About Us
Products
Request a Quote
Product Types
Proportional Pressure Regulator
QKL-B1H; Low Pressure Proportional Regulator (0 - 8 bar)
QKL-B1T, QKL-B3-1, QKL-B3-1A; Low Pressure Proportional Regulator (0 - 8 bar)
QKL-B1S, QKL-B3H; Medium Pressure Proportional Regulator (0 - 30 bar)
QKL-B4H; High Pressure Proportional Regulator/ Controller (0 - 18bar; 0 - 70bar)
Air Pressure Ratio Regulator (0-103bar)
Single-Valve Dynamic Pressure Controller
Steam, Water Proportional Pressure Regulator
Ultra High Resolution Proportional Pressure Regulator
Proportional Flow Control Valves
Electronic Flow Control Valve - Pneumatic Air Flow Controller
MEMS Gas Mass Flow Meter 0-1000L/min
Proportional Solenoid Valve 0-310L/min
Stepper-Controlled Proportional Valve 0-1200L/min
Stepper-Controlled Proportional Valve 0-230L/min
Stepper-Controlled Proportional Valve 0-400L/min
Stepper-Controlled Proportional Valve 0-5000L/min
Stepper-Controlled Proportional Valve 0-65L/min
Pinch Valve
Electronic Pinch Valve, Flow Control Pinch Valve
Cylinder Pinch Valve
Proportional Pinch Valve
Medical Biotechnology Valves
BDRI Series|Fluid/ Liquid Level Sensor
Conductivity Sensor|General/Liquid/Electric Conductivity Sensor
Gross Occlusion Detector
Non-Invasive Flow Sensor
Point Level Detector
PPSU High Temperature Connector
Medical Pressure Sensor
Push In Fittings, Stainless Steel Fittings
Push-in Function Fittings PPSU
PVDF Corrosion Resistant Joints
Medical Solenoid Valve
Temperature Sensor
Ultrasonic Air Bubble DetectorAir Bubble Sensor
Back Pressure Regulators
Back Pressure Regulators-BD Series
Back Pressure Regulators-GS Series
Back Pressure Regulators-Research Series
Pneumatic Cylinders
Diaphragm Cylinder -FC series
MA/MAC Stainless Steel Cylinder With Cushioning
ISO 6432 Cylinder
MAL Series Cylinder
SC Series Standard Cylinder
SDA Cylinder
SI Series Cylinder
Air Control Valves
Cylinder Gas Control Valve
Piston Actuated Valve 100 Series
Y-type Steam Valve
Vacuum Solenoid Valves
1/4"~1" 3/2 Way Solenoid Valve
3/4"~1"1/2 3/2 Way Solenoid Valve
VS Series
Vacuum Generators
VBI (Multi-Stage)
VBM (Multi-Stage)
VBR (Multi-Stage)
VBT (Multi-Stage)
Vacuum Filters
Vacuum Pneumatic Valves
Contitech Air Springs
C Series Fixed Connection
D Series Detachable Connection
R Series Wheel Snap Ring Connection
S Series Plastic Connectors
Solenoid Valves
3/2 Way Solenoid Valve MS10 Series
5/2 Way - KLSY Series Low Power Consumption Solenoid Valve
1/4"~1" 3/2 Way Solenoid Valves
3/4"~1"1/2 3/2 Way Solenoid Valves
3/2 Way Solenoid Valves (25bar)
ISO1 5/2 Way/Single Coil Solenoid Valves
ISO1 5/3 Way Solenoid Valves
ISO1.2 5/2 Way Solenoid Valves
ISO1 5/2 way/Double Coil
1/4" 5/2, 5/3 Way Solenoid Valves
1/4" 5/2, 5/3 Way Solenoid Valves
1/8" 5/2, 5/3 Way Solenoid Valves
3/8" 5/2, 5/3 Way Solenoid Valves
1/8", 1/4" 5/2, 5/3 Way Solenoid Valves
1/2" 5/2, 5/3 Way Solenoid Valves
C Series Fixed Connection
Specifications
Monolayer
model
Minimum installation height (mm)
Max Diameter (mm)
Installation space requirements (mm)
Maximum stroke (mm)
Force at p = 8 bar
Minimum stroke force (kN)
Travel at half strength (kN)
Maximum stroke force (kN)
Recommended height (mm)
FS 40-6CI
50
145
160
60
6.9
5.2
2.4
90
FS 50-5CI
51
150
165
44
9.0
5.4
2.2
75
FS 70-7CI
51
165
180
64
9.9
7.5
5.2
90
FS 100-10CI
51
210
225
94
14.7
11.0
1.6**
115
FS 120-9CI
50
215
230
85
17.7
12.4
6.6
110
FS 120-10CI
51
231
245
99
19.5
15.0
4.6
115
FS 120-12CI
51
235
250
119
18.7
15.9
7.2
140
FS 200-10CI
51
250
265
89
23.8
17.5
9.1
110
FS 330-11CI
51
325
340
99
43.9
36.7
22.4
130
FS 330-14CI
51
343
360
129
47.3
37.8
13.0
140
FS 530-11CI
51
385
400
124
68.4
53
20.8
145
FS 530-14CI
51
405
420
134
69.6
60.2
35.2
150
FS 960-12CI
63
450
480
117
98.3
78.2
40.4
130
FS 1330-11CI
63
530
570
107
141.6
121.9
63.2***
131
Double
model
Minimum installation height (mm)
Max Diameter (mm)
Installation space requirements (mm)
Maximum stroke (mm)
Force at p = 8 bar
Minimum stroke force (kN)
Travel at half strength (kN)
Maximum stroke force (kN)
Recommended height (mm)
FD 40-10CI
70
145
160
100
7.4
5.5
2.5
160
FD 70-13CI
72
165
180
128
11.6
7.8
2.6
175
FD 110-15CI
72
203
215
156
16.5
10.5
2.9
175
FD 120-17CI
75
215
230
155
18.0
13.1
6.3
190
FD 120-20CI
77
218
235
193
19.6
14.4
6.6
205
FD 200-19CI
75
250
265
200
26.1
18.3
5.7
210
FD 200-22CI
77
255
265
218
26.2
17.6
7.0
220
FD 200-25CI
77
260
275
248
25.4
18.8
8.2
254
FD 330-22CI
75
325
340
230
46.4
33.8
14.3
240
FD 330-30CI*
77
340
355
283
49.0
39.6
13.7
-
FD 530-22CI
77
385
400
233
65.5
52.9
21.8
250
FD 530-30CI
77
400
415
273
71.2
56.4
21.6
260
FD 530-35CI
77
405
420
313
74.8
57.9
21.0***
285
FD 960-22CI
95
444
490
225
101.0
81.1
37.0
240
FD 1330-25CI
92
518
570
243
145.4
113.0
46.5***
246
Layer
model
Minimum installation height (mm)
Max Diameter (mm)
Installation space requirements (mm)
Maximum stroke (mm)
Force at p = 8 bar
Minimum stroke force (kN)
Travel at half strength (kN)
Maximum stroke force (kN)
Recommended height (mm)
FT 330-29CI*
110
325
345
320
46.4
33.7
17.8
-
FT 430-32CI*
115
330
355
315
53.4
39.2
17.0
-
FT 530-32CI*
110
384
410
325
69.3
54.6
24.7
-
FT 530-35CI*
115
405
430
395
77.0
53.8
27.2
-
FT 960-34CI*
120
462
510
335
99.9
77.2
32.0
-
FT 1330-35CI*
120
521
570
350
148.2
119.6
26.3****
-